Range extender battery management system alerts
Browse 191 HVREX alert codes and open an entry for its description and recorded conditions.
HVREX alert codes
Showing 101–150 of 191
- HVREX_a367 — Hv Big Prefetch Abort HVREX_a367_HvBigPrefetchAbort There has been a CPU prefetch abort exception.
- HVREX_a368 — Hv Big Prefetch Abort Trace HVREX_a368_HvBigPrefetchAbortTrace CPU Prefetch Abort core backtrace data.
- HVREX_a369 — Hv Big Data Abort HVREX_a369_HvBigDataAbort There has been a CPU data abort exception.
- HVREX_a372 — Hv Big Data Abort Trace HVREX_a372_HvBigDataAbortTrace CPU Data Abort core backtrace data.
- HVREX_a374 — Cancore Tx Message Drop HVREX_a374_CancoreTxMessageDrop HVBIG dropped a message in cancore that it was attempting to transmit.
- HVREX_a375 — Cancore Rx Message Drop HVREX_a375_CancoreRxMessageDrop HVBIG dropped a received message in cancore that it was attempting to deliver to a client.
- HVREX_a376 — Enet Dma Overrun HVREX_a376_EnetDmaOverrun HVBATT didn't transmit an Etherloop message due to DMA failure.
- HVREX_a377 — Eth Tx Overrun HVREX_a377_EthTxOverrun HVBATT didn't transmit an Etherloop message due to enet queue full.
- HVREX_a378 — Phy Crc Error HVREX_a378_PhyCrcError There are 10 or more receive or transmit CRC errors in HVBATT ethernet PHY's frames.
- HVREX_a379 — Hv Big High Cpu Load HVREX_a379_HvBigHighCpuLoad High cpu load was detected across the RTOS tasks
- HVREX_a380 — Hv Big High Stack Usage HVREX_a380_HvBigHighStackUsage High stack usage was detected in one of the RTOS tasks
- HVREX_a381 — Hv Big Watchdog Violation HVREX_a381_HvBigWatchdogViolation The processor has experienced a watchdog violation due to an unserviced watchdog. Stack trace values have been dumped from the application.
- HVREX_a382 — Hv Big Watchdog Warning HVREX_a382_HvBigWatchdogWarning A task did not check in on time.
- HVREX_a383 — Hv Big Sw Assertion HVREX_a383_HvBigSwAssertion There has been a failed software assertion.
- HVREX_a384 — Hv Big Sw Assertion Program Counter HVREX_a384_HvBigSwAssertionProgramCounter The program counter at the location of the failed software assertion.
- HVREX_a385 — Hv Big Sw Assertion Link Register HVREX_a385_HvBigSwAssertionLinkRegister The link register at the location of the failed software assertion.
- HVREX_a386 — Hv Big Rtos Stack Overflow Abort HVREX_a386_HvBigRtosStackOverflowAbort An RTOS task encountered a stack overflow.
- HVREX_a387 — Phy Crc Warning HVREX_a387_PhyCrcWarning There are less than 10 receive or transmit CRC errors in HVBATT ethernet PHY's frames.
- HVREX_a388 — Hvs Bus Off HVREX_a388_HvsBusOff The High Voltage System (HVS) bus is in the BusOff state.
- HVREX_a389 — Hvs Bus Error Passive HVREX_a389_HvsBusErrorPassive The High Voltage System (HVS) bus is in the error passive state.
- HVREX_a390 — Hvs Bus Error Warning HVREX_a390_HvsBusErrorWarning One or more of the High Voltage System (HVS) bus error counts has reached the warning limit.
- HVREX_a391 — Trex Bus Off HVREX_a391_TrexBusOff The Range Extender (TREX) bus is in the BusOff state.
- HVREX_a392 — Trex Bus Error Passive HVREX_a392_TrexBusErrorPassive The Range Extender (TREX) bus is in the error passive state.
- HVREX_a393 — Trex Bus Error Warning HVREX_a393_TrexBusErrorWarning One or more of the Range Extender (TREX) bus error counts has reached the warning limit.
- HVREX_a394 — Uds Ecu Reset HVREX_a394_UdsEcuReset HVBATT has been reset over UDS.
- HVREX_a395 — Hv Big Undefined Instruction Abort HVREX_a395_HvBigUndefinedInstructionAbort There has been a CPU undefined instruction exception.
- HVREX_a396 — Hv Big Unknown Abort HVREX_a396_HvBigUnknownAbort The CPU encountered an undefined exception.
- HVREX_a397 — Hv Big Abort Debug Data HVREX_a397_HvBigAbortDebugData Debug data register corresponding to the CPU exception.
- HVREX_a483 — Hv Mon Ipc Data Channel HVREX_a483_HvMonIpcDataChannel The processor has experienced an inter-processor communication error amongst its cores.
- HVREX_a484 — Hv Mon Mem Manage Abort HVREX_a484_HvMonMemManageAbort There has been a CPU MemManage fault exception.
- HVREX_a485 — Destructive Reset HVREX_a485_DestructiveReset The control module memory-mapped (CTRL_MMR) reset source register shows that the last MCU reset came from unexpected sources.
- HVREX_a486 — Hv Mon Prefetch Abort Trace HVREX_a486_HvMonPrefetchAbortTrace CPU Prefetch Abort core backtrace data.
- HVREX_a487 — Board Power On Reset HVREX_a487_BoardPowerOnReset The CTRL_MMR reset source register shows that the last MCU reset came from a board power on
- HVREX_a490 — Hv Mon Data Abort Trace HVREX_a490_HvMonDataAbortTrace CPU Data Abort core backtrace data.
- HVREX_a491 — Hv Mon Hard Fault Abort HVREX_a491_HvMonHardFaultAbort There has been a CPU hard fault exception.
- HVREX_a492 — Hv Mon Watchdog Violation HVREX_a492_HvMonWatchdogViolation The processor has experienced a watchdog violation due to an unserviced watchdog. Stack trace values have been dumped from the application.
- HVREX_a493 — Hv Mon Watchdog Warning HVREX_a493_HvMonWatchdogWarning A task did not check in on time.
- HVREX_a496 — Hv Mon Shunt Data Invalid HVREX_a496_HvMonShuntDataInvalid The shunt measurement by HVCON shared memory transfer contains a SPI communication fault or CRC mismatch
- HVREX_a497 — Hv Mon Shunt Over Current HVREX_a497_HvMonShuntOverCurrent Warns if the shunt current (discharge or charge) is above max current limit.
- HVREX_a498 — Hv Mon Bmb Transfer Mia HVREX_a498_HvMonBmbTransferMia The BMB measurement by HVCON shared memory transfer is not producing data
- HVREX_a499 — Hv Mon Bmb Voltages Invalid HVREX_a499_HvMonBmbVoltagesInvalid The BMB brick voltage measurements by HVCON shared memory transfer contains an ISOSPI communication fault or CRC mismatch
- HVREX_a500 — Hv Mon Bmb Over Voltage HVREX_a500_HvMonBmbOverVoltage A brick voltage is above the fault voltage limit
- HVREX_a501 — Hv Mon Bmb Under Voltage HVREX_a501_HvMonBmbUnderVoltage A brick voltage is above the fault voltage limit
- HVREX_a502 — Hv Mon Bmb Over Temperature HVREX_a502_HvMonBmbOverTemperature A module temperature is above the warning temperature limit
- HVREX_a504 — Hv Mon Bmb Temperatures Invalid HVREX_a504_HvMonBmbTemperaturesInvalid The BMB thermistor measurements by HVCON shared memory transfer contains an ISOSPI communication fault or CRC mismatch
- HVREX_a505 — Hv Mon High Cpu Load HVREX_a505_HvMonHighCpuLoad High cpu load was detected across the RTOS tasks
- HVREX_a506 — Hv Mon High Stack Usage HVREX_a506_HvMonHighStackUsage High stack usage was detected in one of the RTOS tasks
- HVREX_a507 — Hv Mon Sw Assertion HVREX_a507_HvMonSwAssertion There has been a failed software assertion.
- HVREX_a508 — Hv Mon Sw Assertion Program Counter HVREX_a508_HvMonSwAssertionProgramCounter The program counter at the location of the failed software assertion.
- HVREX_a509 — Hv Mon Sw Assertion Link Register HVREX_a509_HvMonSwAssertionLinkRegister The link register at the location of the failed software assertion.