Skip to content

VCSUPER_a284 — Chiller Exv Fault

Full alert identifier: VCSUPER_a284_chillerExvFault

Alert description

The vehicle controller detects the chiller electronic expansion valve (EXV) motor driver is reporting an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning and heating may be limited or unavailable. Powertrain performance may be limited.

Set condition

The chiller EXV motor driver is reporting an electrical condition (short or disconnect).

Clear condition

The chiller EXV motor driver no longer reports an electrical condition (short or disconnect).

Signals to check

These diagnostic fields are associated with VCSUPER_a284. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCSUPER_a284_chargePumpUndervoltage —
Driver Has Comm Error VCSUPER_a284_driverHasCommError —
Driver State VCSUPER_a284_driverState —
Driver Therm Shutdown VCSUPER_a284_driverThermShutdown —
Driver Therm Warn VCSUPER_a284_driverThermWarn —
Is Coil Open X VCSUPER_a284_isCoilOpenX —
Is Coil Open Y VCSUPER_a284_isCoilOpenY —
Is Coil Short XN Gnd VCSUPER_a284_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCSUPER_a284_isCoilShortXNVbb —
Is Coil Short XP Gnd VCSUPER_a284_isCoilShortXPGnd —
Is Coil Short XP Vbb VCSUPER_a284_isCoilShortXPVbb —
Is Coil Short YN Gnd VCSUPER_a284_isCoilShortYNGnd —
Is Coil Short YN Vbb VCSUPER_a284_isCoilShortYNVbb —
Is Coil Short YP Gnd VCSUPER_a284_isCoilShortYPGnd —
Is Coil Short YP Vbb VCSUPER_a284_isCoilShortYPVbb —
Undervoltage VCSUPER_a284_undervoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSUPER_a284.

Browse all VCSUPER alert codes