Skip to content

VCSUPER_a137 — Refrig Disch Pres Sns

Full alert identifier: VCSUPER_a137_refrigDischPresSns

Alert description

The vehicle controller detects the refrigerant discharge pressure sensor is experiencing an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

The refrigerant discharge pressure sensor reads a power rail or ground reference voltage.

Clear condition

The refrigerant discharge pressure sensor no longer reads a power rail or ground reference voltage.

Signals to check

These diagnostic fields are associated with VCSUPER_a137. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Sns Disconnect VCSUPER_a137_snsDisconnect —
Sns Rate Change Down VCSUPER_a137_snsRateChangeDown —
Sns Rate Change Up VCSUPER_a137_snsRateChangeUp —
Sns Short Circuit VCSUPER_a137_snsShortCircuit —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSUPER_a137.

Browse all VCSUPER alert codes