VCSEC_a212 — Sniffer RSSIMIA
Full alert identifier: VCSEC_a212_snifferRSSIMIA
Alert description
Connection sniffer endpoints are not reporting connection signal strength
Potential impact
Reduced passive entry performance
Set condition
Center endpoint has valid RSSI values but sniffer does not
Clear condition
Driver no longer present and 10 seconds after handle pull
Signals to check
These diagnostic fields are associated with VCSEC_a212. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Access Address Invalid
VCSEC_
|
— |
Sniffer Channel Missing
VCSEC_
|
— |
Sniffer MIA Cradle
VCSEC_
|
— |
Sniffer MIA Front
VCSEC_
|
— |
Sniffer MIA Front Left
VCSEC_
|
— |
Sniffer MIA Front Right
VCSEC_
|
— |
Sniffer MIA Left
VCSEC_
|
— |
Sniffer MIA Rear
VCSEC_
|
— |
Show 4 more fields
| Signal | Unit |
|---|---|
Sniffer MIA Rear Left
VCSEC_
|
— |
Sniffer MIA Rear Right
VCSEC_
|
— |
Sniffer MIA Right
VCSEC_
|
— |
Sniffer MIA Secondary
VCSEC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSEC_a212.