Skip to content

VCSEC_a211 — Handle Pull Without Auth

Full alert identifier: VCSEC_a211_handlePullWithoutAuth

Alert description

Door handle pulled without an authenticated device

Potential impact

May indicate passive entry failure

Set condition

Door handle pulled without auth

Clear condition

Ten second period without unauthenticated handle pull

Signals to check

These diagnostic fields are associated with VCSEC_a211. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Auth Requested VCSEC_a211_AuthRequested —
Device Present Count VCSEC_a211_DevicePresentCount —
Maximum RSSI VCSEC_a211_MaximumRSSI —
Maximum RSSI Antenna VCSEC_a211_MaximumRSSIAntenna —
RSSI Valid Matrix VCSEC_a211_RSSIValidMatrix —
Unknown Device Present VCSEC_a211_UnknownDevicePresent —
Connection Count VCSEC_a211_connectionCount —
Handle Pulled VCSEC_a211_handlePulled —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSEC_a211.