VCRIGHT_a477 — Front Light Bar Internal Error
Full alert identifier: VCRIGHT_a477_frontLightBarInternalError
Alert description
An internal condition affecting the front light bar functionality has been detected - certain light functions may be degraded or disabled.
Potential impact
Certain light functions may be degraded or disabled.
Set condition
One or more lighting matrix managers report one or more internal faults.
Clear condition
All lighting matrix managers report no faults.
Signals to check
These diagnostic fields are associated with VCRIGHT_a477. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Led Open
VCRIGHT_
|
— |
Led Short
VCRIGHT_
|
— |
Over Current
VCRIGHT_
|
— |
Under Current
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a477.