Skip to content

VCRIGHT_a461 — Pwr Glovebox Uncal

Full alert identifier: VCRIGHT_a461_pwrGloveboxUncal

Alert description

The glovebox is uncalibrated. The glovebox may not move as expected.

Potential impact

The glovebox will not move correctly.

Set condition

The glovebox calibration routine runs unsuccessfully or the glovebox become uncalibrated during use.

Clear condition

The glovebox calibration routine is succesfully run or the glovebox is successfully calibrated using the UI control.

Signals to check

These diagnostic fields are associated with VCRIGHT_a461. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bin Position VCRIGHT_a461_binPosition mm
Motor Position VCRIGHT_a461_motorPosition counts
Uncal Reason VCRIGHT_a461_uncalReason
0
NONE SNA
1
START CAL
2
OPEN AT INIT
3
IRRATIONAL POS
4
FAILED TO LATCH
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a461.

Browse all VCRIGHT alert codes