Skip to content

VCRIGHT_a459 — Seat Heat Rail Test Diagnostics

Full alert identifier: VCRIGHT_a459_seatHeatRailTestDiagnostics

Alert description

Fused rail driver or downstream load driver test result stale.

Potential impact

May not be able to detect fused rail driver or downstream load driver stuck-on condition.

Set condition

Any required fused rail driver or downstream load driver test has not been completed within the last 24h.

Clear condition

All required fused rail driver and downstream load driver tests completed within the last 24h.

Signals to check

These diagnostic fields are associated with VCRIGHT_a459. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Downstream Output Voltage VCRIGHT_a459_downstreamOutputVoltage V
Seat Heat Could Not Power Off VCRIGHT_a459_seatHeatCouldNotPowerOff —
Seat Heat Result Stale VCRIGHT_a459_seatHeatResultStale —
Upstream Current VCRIGHT_a459_upstreamCurrent A
Upstream Load Test Result Stale VCRIGHT_a459_upstreamLoadTestResultStale —
Upstream Result Stale VCRIGHT_a459_upstreamResultStale —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a459.

Browse all VCRIGHT alert codes