VCRIGHT_a144 — Evaporator Temp Sns

Full alert identifier: VCRIGHT_a144_evaporatorTempSns

Alert description

The evaporator temperature sensor has an electrical fault

Potential impact

Cabin climate control system performance may be limited

Set condition

The sensor is disconnected or short-circuited to ground

Clear condition

Sensor fault not longer detected

Signals to check

These diagnostic fields are associated with VCRIGHT_a144. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Sns Disconnect VCRIGHT_a144_snsDisconnect —
Sns Rate Change Down VCRIGHT_a144_snsRateChangeDown —
Sns Rate Change Up VCRIGHT_a144_snsRateChangeUp —
Sns Short Circuit VCRIGHT_a144_snsShortCircuit —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a144.

Browse all VCRIGHT alert codes