VCREAR_a442 — Tailgate Left Latch Undercurrent
Full alert identifier: VCREAR_a442_tailgateLeftLatchUndercurrent
Alert description
The tailgate latch motor drew less current than expected during an actuation.
Potential impact
The tailgate latch harness connection or motor may be degraded.
Set condition
The tailgate latch motor draws less than 200mA for over 250ms during an actuation.
Clear condition
The tailgate latch begins a new actuation.
Signals to check
These diagnostic fields are associated with VCREAR_a442. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp
VCREAR_
|
degC |
Detent Switch Active
VCREAR_
|
— |
Forkbolt 1 Switch Active
VCREAR_
|
— |
Forkbolt 2 Switch Active
VCREAR_
|
— |
Home Switch Active
VCREAR_
|
— |
Latch State
VCREAR_
|
— |
Peak Current A
VCREAR_
|
A |
State Duration Ms
VCREAR_
|
ms |
Show 1 more field
| Signal | Unit |
|---|---|
Vbus 15 Vsw
VCREAR_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a442.