VCREAR_a350 — Ens Out Of Range
Full alert identifier: VCREAR_a350_ensOutOfRange
Alert description
The Emergency Notification Signal (ENS) harness may be disconnected or the Restraints Control Module (RCM) may be missing (MIA).
Potential impact
Loss of redundancy on high voltage disconnection signal.
Set condition
Emergency Notification Signal (ENS) period is not within 10% of 0.001 or 0.1 seconds, and duty cycle is not between 60% and 40%.
Clear condition
ENS period is within 10% of 0.001 or 0.1 seconds and duty cycle is between 60% and 40%.
Signals to check
These diagnostic fields are associated with VCREAR_a350. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ens Duty
VCREAR_
|
% |
Ens Period
VCREAR_
|
s |
Ens Timed Out
VCREAR_
|
— |
Check other alerts