Skip to content

VCREAR_a139 — Nvm Redundancy Loss

Full alert identifier: VCREAR_a139_NvmRedundancyLoss

Alert description

The Electronic Parking Brake or Electronic Parking Brake Monitor took longer than expected to save caliper state in non-volatile memory.

Potential impact

Non-volatile memory error due to Electronic Parking Brake and Electronic Parking Brake Monitor mismatch

Set condition

Caliper state saved to Electronic Parking Brake and Electronic Parking Brake Monitor mismatched for more than 500ms

Clear condition

Electronic Parking Brake and Electronic Parking Brake Monitor states match

Signals to check

These diagnostic fields are associated with VCREAR_a139. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Local State VCREAR_a139_localState
0
UNSAVED
1
UNKNOWN
2
REAPPLY
3
PARK
4
OPEN
5
SERVICE
6
WINCHMODE
—
Monitor State VCREAR_a139_monitorState
0
UNSAVED
1
UNKNOWN
2
REAPPLY
3
PARK
4
OPEN
5
SERVICE
6
WINCHMODE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a139.

Browse all VCREAR alert codes