VCREAR_a128 — Motor P Volt High

Full alert identifier: VCREAR_a128_MotorPVoltHigh

Alert description

Motor positive lead voltage is greater than 6.0 volts while inactive

Potential impact

Caliper motor or harness may be damaged

Set condition

The Electronic Parking Brake motor is idle, and the positive lead voltage measurement is higher than 6.0 volts.

Clear condition

Caliper state machine exits csmState CSM_FAULT

Signals to check

These diagnostic fields are associated with VCREAR_a128. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
12 V Filt VCREAR_a128_12vFilt V
Nv Filt VCREAR_a128_nvFilt V
Pv Filt VCREAR_a128_pvFilt V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a128.