VCLEFT_a359 — Post POR Excessive Ah
Full alert identifier: VCLEFT_a359_postPORExcessiveAh
Alert description
After a vehicle power-on-reset (POR), the vehicle controller detects the low voltage (LV) battery has consumed too many Amp hours (Ah) during its initial charge, indicating the LV battery was deeply discharged prior to the power-on-reset.
Potential impact
The LV battery may be unable to hold adequate electrical charge to remain functional. Replacement may be necessary, with a separate alert present to indicate that condition if applicable.
Set condition
The vehicle controller detects the Amp hour (Ah) count going into the low voltage (LV) battery while recharging exceeded its limit.
Clear condition
Next LV battery charging session.
Signals to check
These diagnostic fields are associated with VCLEFT_a359. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bms mia
VCLEFT_
|
— |
IBS Ah
VCLEFT_
|
Ah |
IBS Volts
VCLEFT_
|
V |
Pcs mia
VCLEFT_
|
— |
Battery SM State
VCLEFT_
|
— |
Bms State
VCLEFT_
|
— |
Coolant Has Been Filled
VCLEFT_
|
— |
Crash Detected
VCLEFT_
|
— |
Show 4 more fields
| Signal | Unit |
|---|---|
Dcdc LV Support Status
VCLEFT_
|
— |
Hv State
VCLEFT_
|
— |
Service Mode
VCLEFT_
|
— |
Vehicle Power State
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a359.