Alert description

The low voltage (LV) battery has reached its voltage floor before it has reached its Amp hour (Ah) budget. May indicate the LV battery has low charge capacity.

Potential impact

The LV battery may have low discharge capacity, limiting its ability to support the vehicle's low voltage electrical system.

Set condition

The measured LV battery voltage has reached its floor before its Amp hour budget floor.

Clear condition

The measured LV battery voltage remains above the voltage floor after the Amp hour budget is discharged.

Signals to check

These diagnostic fields are associated with VCLEFT_a219. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
IBS Ah VCLEFT_a219_IBSAh Ah
IBS Current VCLEFT_a219_IBSCurrent A
IBS Volts VCLEFT_a219_IBSVolts V