Skip to content

VCLEFT_a201 — Precharge Failed

Full alert identifier: VCLEFT_a201_prechargeFailed

Alert description

The Left Vehicle Controller (VCLEFT) precharge circuit did not raise the voltage to the target voltage in the expected amount of time.

Potential impact

The load being precharged may not turn on. Vehicle functions relying on the load being precharged may not operate as expected.

Set condition

The load voltage does not meet the power source voltage in the expected amount of time.

Clear condition

The desired power feed is no longer requested or VCLEFT is reset.

Signals to check

These diagnostic fields are associated with VCLEFT_a201. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Load Voltage VCLEFT_a201_loadVoltage V
Precharge Channel VCLEFT_a201_prechargeChannel —
Source Voltage VCLEFT_a201_sourceVoltage V
Timeout VCLEFT_a201_timeout ms

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a201.

Browse all VCLEFT alert codes