Skip to content

VCLEFT_a192 — Rad Fan General Fault

Full alert identifier: VCLEFT_a192_radFanGeneralFault

Alert description

The radiator fan brushless motor controller reports a condition affecting its operation.

Potential impact

The radiator fan will not be able to run.

Set condition

The radiator fan motor controller reports a condition affecting the radiator fan operation.

Clear condition

The radiator fan motor controller no longer reports an issue affecting the radiator fan operation.

Signals to check

These diagnostic fields are associated with VCLEFT_a192. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Voltage Irrational VCLEFT_a192_busVoltageIrrational —
Bus Voltage Unhealthy VCLEFT_a192_busVoltageUnhealthy —
Chip Overtemp VCLEFT_a192_chipOvertemp —
Dc Current Irrational VCLEFT_a192_dcCurrentIrrational —
Dc Overcurrent VCLEFT_a192_dcOvercurrent —
Ecu Reset VCLEFT_a192_ecuReset —
Fet Temp Irrational VCLEFT_a192_fetTempIrrational —
Hardware Overcurrent VCLEFT_a192_hardwareOvercurrent —
Show 25 more fields
Signal Unit
Hs Vds Overvoltage VCLEFT_a192_hsVdsOvervoltage —
Hs Vds Overvoltage Mask VCLEFT_a192_hsVdsOvervoltageMask —
Lin Checksum Error VCLEFT_a192_linChecksumError —
Lin Framing Error VCLEFT_a192_linFramingError —
Ls Vds Overvoltage VCLEFT_a192_lsVdsOvervoltage —
Ls Vds Overvoltage Mask VCLEFT_a192_lsVdsOvervoltageMask —
Motor Control Error VCLEFT_a192_motorControlError —
Motor Faulted VCLEFT_a192_motorFaulted —
Motor Locked VCLEFT_a192_motorLocked —
Motor Open Phase VCLEFT_a192_motorOpenPhase —
Motor Overtemp VCLEFT_a192_motorOvertemp —
Motor Phase Current Irrational VCLEFT_a192_motorPhaseCurrentIrrational —
Motor Soft Open Phase VCLEFT_a192_motorSoftOpenPhase —
Motor Speed Irrational VCLEFT_a192_motorSpeedIrrational —
Motor Speed Too High VCLEFT_a192_motorSpeedTooHigh —
Motor Stalled VCLEFT_a192_motorStalled —
Over Voltage VCLEFT_a192_overVoltage —
Payload Bits Not Set VCLEFT_a192_payloadBitsNotSet —
Phase Overcurrent VCLEFT_a192_phaseOvercurrent —
Phase Shorted VCLEFT_a192_phaseShorted —
Self Test Failed VCLEFT_a192_selfTestFailed —
Self Test Result VCLEFT_a192_selfTestResult
0
NOT TESTED
1
SHORT SUPPLY
2
SHORT GROUND
3
OPEN PHASE U
4
OPEN PHASE V
5
OPEN PHASE W
6
UNKNOWN
7
PASSED
—
Supply Voltage Irrational VCLEFT_a192_supplyVoltageIrrational —
Under Voltage VCLEFT_a192_underVoltage —
Vdda Overcurrent VCLEFT_a192_vddaOvercurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a192.

Browse all VCLEFT alert codes