VCLEFT_a142 — eFuse Management Continuous16 V

Full alert identifier: VCLEFT_a142_eFuseManagementContinuous16V

Alert description

Unexpected voltage seen on continuous device outputs

Potential impact

Electrical loads for Hydraulic Control Unit (HCU) Electronic Stability Program (ESP) Anti-lock Braking System (ABS) wake line, 1st row seat backrest ventilation fan, 1st row seat cushion ventilation fan, spare (frunk, console, side) High-Side Drivers (HSDs), frunk emergency release switch LED, footwell LED, and B-pillar camera heater may be unavailable.

Set condition

Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven

Clear condition

Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.

Signals to check

These diagnostic fields are associated with VCLEFT_a142. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Continuous 16 VE Fuse Monitor VCLEFT_a142_continuous16VEFuseMonitor V
E Fuse Trip Count VCLEFT_a142_eFuseTripCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a142.

Browse all VCLEFT alert codes