Skip to content

VCLEFT_a096 — HVBATTCON MIA

Full alert identifier: VCLEFT_a096_HVBATTCON_MIA

Alert description

One or more of the messages the vehicle controller receives periodically from the High Voltage Battery Management System Controller (HVBATTCON) is not received, indicating the HVBATTCON may be unavailable (MIA).

Potential impact

Vehicle functions that depend on the HVBATTCON may be unavailable or may not function as expected.

Set condition

The vehicle controller does not receive one or more of the expected messages from the HVBATTCON within the expected time frame.

Clear condition

The vehicle controller receives the expected messages from the HVBATTCON.

Signals to check

These diagnostic fields are associated with VCLEFT_a096. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
EGGLEFTPRIV Bmb Thermistor Min Max VCLEFT_a096_EGGLEFTPRIV_bmbThermistorMinMax —
EGGLEFTPRIV Charge Info VCLEFT_a096_EGGLEFTPRIV_chargeInfo —
EGGLEFTPRIV Charge Status VCLEFT_a096_EGGLEFTPRIV_chargeStatus —
EGGLEFTPRIV Network Management VCLEFT_a096_EGGLEFTPRIV_networkManagement —
EGGLEFTPRIV Pack Config VCLEFT_a096_EGGLEFTPRIV_packConfig —
EGGLEFTPRIV Self Test VCLEFT_a096_EGGLEFTPRIV_selfTest —
EGGLEFTPRIV Status VCLEFT_a096_EGGLEFTPRIV_status —
LOOP Charge Info VCLEFT_a096_LOOP_chargeInfo —
Show 2 more fields
Signal Unit
LOOP Energy Status VCLEFT_a096_LOOP_energyStatus —
LOOP Grid Form Info VCLEFT_a096_LOOP_gridFormInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a096.

Browse all VCLEFT alert codes