Skip to content

VCLEFT1_a241 — Di Output Locked

Full alert identifier: VCLEFT1_a241_diOutputLocked

Alert description

A request to change the DI power state has been denied.

Potential impact

Drive inverter may be faulted

Set condition

Electronic Parking Brake Left detects drive inverter lockout request timed out after 0.5 seconds

Clear condition

Electronic Parking Brake Left unlocks drive inverter output

Signals to check

These diagnostic fields are associated with VCLEFT1_a241. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current State VCLEFT1_a241_currentState —
Desired State VCLEFT1_a241_desiredState —
Di Keep Alive VCLEFT1_a241_diKeepAlive —
Epb Sys Status VCLEFT1_a241_epbSysStatus —
Has Lockout Request VCLEFT1_a241_hasLockoutRequest —
High Current VCLEFT1_a241_highCurrent —
Monitor Data Good VCLEFT1_a241_monitorDataGood —
Vehicle Power State VCLEFT1_a241_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT1_a241.

Browse all VCLEFT1 alert codes