VCLEFT1_a126 — Motor N Volt Low
Full alert identifier: VCLEFT1_a126_MotorNVoltLow
Alert description
Motor negative lead voltage measurement is less than 0.5 volts while inactive
Potential impact
Caliper motor or harness may be damaged
Set condition
The Electronic Parking Brake motor is idle, and the negative lead voltage measurement is lower than 0.5 volts.
Clear condition
Caliper state machine exits csmState CSM_FAULT
Signals to check
These diagnostic fields are associated with VCLEFT1_a126. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
12 V Filt
VCLEFT1_
|
V |
Nv Filt
VCLEFT1_
|
V |
Pv Filt
VCLEFT1_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT1_a126.