VCLEFT1_a124 — Cal Out Of Bounds
Full alert identifier: VCLEFT1_a124_calOutOfBounds
Alert description
The 0 drive offset current captured as calibration was higher than expected.
Potential impact
Caliper, Electronic Parking Brake controller, or harness could be damaged. Components may be damaged by high temperatures
Set condition
The calibration offset current measured when motor is not being driven was higher than 3.0 amps
Clear condition
Caliper state machine exits csmState CSM_FAULT
Signals to check
These diagnostic fields are associated with VCLEFT1_a124. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cal Out Of Bounds Data
VCLEFT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT1_a124.