VCLEFT1_a123 — Uc
Full alert identifier: VCLEFT1_a123_Uc
Alert description
Motor current was lower than expected
Potential impact
Caliper could be disconnected or the harness is damaged.
Set condition
Motor current measurement, with calibration offset subtracted, was lower than 0.25 amps
Clear condition
Caliper state machine exits csmState CSM_FAULT
Signals to check
These diagnostic fields are associated with VCLEFT1_a123. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Filtered Current Cal
VCLEFT1_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT1_a123.