Skip to content

VCFRONT_a540 — Right Fog Light Guide Light Fault

Full alert identifier: VCFRONT_a540_rightFogLightGuideLightFault

Alert description

An electrical error has been detected with the right fog light guide (white light pipe in front fascia that turns on along with fog light).

Potential impact

The right fog light guide may not be working.

Set condition

The high side driver (HSD) for the right fog light guide reports that an undercurrent or short circuit condition is present.

Clear condition

The undercurrent or short circuit condition is no longer present.

Signals to check

These diagnostic fields are associated with VCFRONT_a540. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current Sense Faulted VCFRONT_a540_currentSenseFaulted —
Output Faulted VCFRONT_a540_outputFaulted —
Over Current VCFRONT_a540_overCurrent —
Over Temperature VCFRONT_a540_overTemperature —
Temp Sense Faulted VCFRONT_a540_tempSenseFaulted —
Under Current VCFRONT_a540_underCurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a540.

Browse all VCFRONT alert codes