Skip to content

VCFRONT_a488 — Dif Voltage Mismatch

Full alert identifier: VCFRONT_a488_difVoltageMismatch

Alert description

There is a greater than 0.5V drop between input power to the front vehicle controller and the front drive inverter circuit.

Potential impact

Potential hardware issue could cause eFuse to trip or VOR.

Set condition

0.5V difference between input voltage to the board and the eFuse.

Clear condition

Less than 0.5V difference between input voltage to the board and the eFuse

Signals to check

These diagnostic fields are associated with VCFRONT_a488. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
E Fuse Voltage VCFRONT_a488_eFuseVoltage V
Vbat Prot Voltage VCFRONT_a488_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a488.

Browse all VCFRONT alert codes