Skip to content

VCFRONT_a446 — Cabin HVAC Unavailable Context

Full alert identifier: VCFRONT_a446_cabinHVACUnavailableContext

Alert description

Condition(s) affecting the thermal management system have reduced cabin heating and/or cooling performance or made cabin heating and/or cooling unavailable.

Potential impact

Cabin heating and/or cooling performance may be limited, or cabin heating and/or cooling may be unavailable.

Set condition

May set due to many possible conditions affecting thermal management system functionality. Alert log signal data should provide information on specific condition(s).

Clear condition

Condition(s) affecting thermal management system functionality no longer detected.

Signals to check

These diagnostic fields are associated with VCFRONT_a446. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Battery Over Temp VCFRONT_a446_batteryOverTemp —
Comp Fault Pd High VCFRONT_a446_compFaultPdHigh —
Comp Fault Pd Low VCFRONT_a446_compFaultPdLow —
Comp Fault Ps Low VCFRONT_a446_compFaultPsLow —
Comp Fault Refrigerant VCFRONT_a446_compFaultRefrigerant —
Comp Fault Td High VCFRONT_a446_compFaultTdHigh —
Comp Standby Coast Down Mode VCFRONT_a446_compStandbyCoastDownMode —
Comp Standby Communication VCFRONT_a446_compStandbyCommunication —
Show 33 more fields
Signal Unit
Comp Standby HV Not Ready VCFRONT_a446_compStandbyHVNotReady —
Comp Standby Low Ambient VCFRONT_a446_compStandbyLowAmbient —
Comp Standby Low Disch Press VCFRONT_a446_compStandbyLowDischPress —
Comp Standby Multiple Pd Cutouts VCFRONT_a446_compStandbyMultiplePdCutouts —
Comp Standby Multiple Td Cutouts VCFRONT_a446_compStandbyMultipleTdCutouts —
Comp Standby Refrig Not Ok VCFRONT_a446_compStandbyRefrigNotOk —
Comp Standby Self Not Ready VCFRONT_a446_compStandbySelfNotReady —
Comp Standby Showroom Mode VCFRONT_a446_compStandbyShowroomMode —
Compressor State VCFRONT_a446_compressorState
0
STANDBY
1
READY
2
RUNNING
3
FAULT
—
Coolant Sys Locked Out VCFRONT_a446_coolantSysLockedOut —
Evap Low Ps Cutout VCFRONT_a446_evapLowPsCutout —
High Suction Superheat VCFRONT_a446_highSuctionSuperheat —
Hp Battery Load Type VCFRONT_a446_hpBatteryLoadType
0
NONE
1
BATT HEAT
2
BATT COOL
—
Hp Cabin Load Type VCFRONT_a446_hpCabinLoadType
0
NONE
1
CC
2
REHEAT
3
EVAP
—
Hp Mode VCFRONT_a446_hpMode —
Hvac System Fault VCFRONT_a446_hvacSystemFault —
Ref Sys Locked Out VCFRONT_a446_refSysLockedOut —
Sensor Droop Pd VCFRONT_a446_sensorDroopPd —
Sensor Has Offset Pd VCFRONT_a446_sensorHasOffsetPd —
Sensor Has Offset Td VCFRONT_a446_sensorHasOffsetTd —
Sensor Has Offset Tl VCFRONT_a446_sensorHasOffsetTl —
Sensor Intermittent Pd VCFRONT_a446_sensorIntermittentPd —
Sensor Intermittent Pl VCFRONT_a446_sensorIntermittentPl —
Sensor Intermittent Ps VCFRONT_a446_sensorIntermittentPs —
Sensor Intermittent Td VCFRONT_a446_sensorIntermittentTd —
Sensor Intermittent Tl VCFRONT_a446_sensorIntermittentTl —
Sensor Intermittent Ts VCFRONT_a446_sensorIntermittentTs —
Using Modeled Pd VCFRONT_a446_usingModeledPd —
Using Modeled Pl VCFRONT_a446_usingModeledPl —
Using Modeled Ps VCFRONT_a446_usingModeledPs —
Using Modeled Td VCFRONT_a446_usingModeledTd —
Using Modeled Tl VCFRONT_a446_usingModeledTl —
Using Modeled Ts VCFRONT_a446_usingModeledTs —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a446.

Browse all VCFRONT alert codes