Skip to content

VCFRONT_a392 — Air Comp Output Stuck On

Full alert identifier: VCFRONT_a392_airCompOutputStuckOn

Alert description

The vehicle controller detects output voltage from the air compressor for the air suspension system when none is expected. The vehicle controller's fused high current eFuse circuit will be used to deenergize the air compressor.

Potential impact

The air compressor for the air suspension system is unavailable, making air suspension functionality limited or unavailable.

Set condition

Air compressor output voltage is detected when the air compressor has been requested off.

Clear condition

Clears automatically on vehicle power state cycle.

Signals to check

These diagnostic fields are associated with VCFRONT_a392. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current VCFRONT_a392_current A
Time Off VCFRONT_a392_timeOff milliseconds
Voltage VCFRONT_a392_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a392.

Browse all VCFRONT alert codes