VCFRONT_a391 — Frunk Latch Switch Fault

Full alert identifier: VCFRONT_a391_frunkLatchSwitchFault

Alert description

Unexpected front trunk (frunk) latch switch values are present, which may result in the frunk state not matching the state indicated in the touchscreen user interface (UI).

Potential impact

The state of the front trunk (frunk) latch (open or closed) may be inaccurate. Front trunk (frunk) state may not match the state indicated in the touchscreen user interface (UI). For example, the UI may report the frunk as open when closed, or closed when open.

Set condition

Both front trunk (frunk) switches are pressed, or both frunk switches are unpressed, or any frunk switch is shorted / disconnected.

Clear condition

Front trunk (frunk) latch switch values are in expected range.

Signals to check

These diagnostic fields are associated with VCFRONT_a391. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Switch 1 Disconnected VCFRONT_a391_switch1Disconnected —
Switch 1 Shorted VCFRONT_a391_switch1Shorted —
Switch 1 Voltage VCFRONT_a391_switch1Voltage mV
Switch 2 Disconnected VCFRONT_a391_switch2Disconnected —
Switch 2 Shorted VCFRONT_a391_switch2Shorted —
Switch 2 Voltage VCFRONT_a391_switch2Voltage mV
Switch Mismatch VCFRONT_a391_switchMismatch —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a391.