Skip to content

VCFRONT_a336 — Pcs Fast Trip OC Max

Full alert identifier: VCFRONT_a336_pcsFastTripOCMax

Alert description

The power conversion system eFuse reported a current value over 200A within the last 10ms.

Potential impact

The eFuse may have tripped.

Set condition

200A eFuse current within last 10ms.

Clear condition

Less than 200A eFuse current.

Signals to check

These diagnostic fields are associated with VCFRONT_a336. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a336_avgCurrent A
Max Current VCFRONT_a336_maxCurrent A
Max Slope VCFRONT_a336_maxSlope A/ms
Vehicle State VCFRONT_a336_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a336.

Browse all VCFRONT alert codes