Skip to content

VCFRONT_a280 — Refrig Liquid Pres Sns

Full alert identifier: VCFRONT_a280_refrigLiquidPresSns

Alert description

The refrigerant liquid pressure sensor has an electrical fault (disconnect, short, or internal). HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Potential impact

HVAC and powertrain performance may be limited.

Set condition

The sensor reads a power rail or ground reference voltage.

Clear condition

The sensor no longer reads a power rail or ground reference voltage.

Signals to check

These diagnostic fields are associated with VCFRONT_a280. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Sns Disconnect VCFRONT_a280_snsDisconnect —
Sns Rate Change Down VCFRONT_a280_snsRateChangeDown —
Sns Rate Change Up VCFRONT_a280_snsRateChangeUp —
Sns Short Circuit VCFRONT_a280_snsShortCircuit —