Skip to content

VCFRONT_a268 — Vbat Fused Voltage Mismatch

Full alert identifier: VCFRONT_a268_vbatFusedVoltageMismatch

Alert description

The front vehicle controller (VCFRONT) detects there is voltage mismatch greater than 0.5V between the input voltage to the VCFRONT printed circuit board assembly (PCBA) and the internally fused VCFRONT low voltage (LV) Battery Power (VBAT Fused) circuit (or eFuse) output voltage.

Potential impact

Vehicle functions that rely on the VCFRONT may be limited or may not function as expected.

Set condition

The voltage mismatch is greater than 0.5V between the VCFRONT PCBA input voltage and the eFuse output voltage.

Clear condition

The voltage mismatch is less than 0.5V between the VCFRONT PCBA input voltage and the eFuse output voltage.

Signals to check

These diagnostic fields are associated with VCFRONT_a268. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
E Fuse Voltage VCFRONT_a268_eFuseVoltage V
Vbat Prot Voltage VCFRONT_a268_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a268.

Browse all VCFRONT alert codes