VCFRONT_a257 — Port Expander VOR
Full alert identifier: VCFRONT_a257_portExpanderVOR
Alert description
The front vehicle controller (VCFRONT) has detected a condition affecting a group of eFuses, making an eFuse system reset necessary.
Potential impact
Vehicle may be unable to drive.
Set condition
VCFRONT detects a group of eFuses with a common power source have all tripped (circuit opened).
Clear condition
The integrated circuit (I2C) port expander connecting the microcontroller and eFuse enable pins is reset after a retry or sleep cycle.
Signals to check
These diagnostic fields are associated with VCFRONT_a257. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Epas 3 P Fault
VCFRONT_
|
— |
Epas 3 S Fault
VCFRONT_
|
— |
Esp Fault
VCFRONT_
|
— |
I Booster Fault
VCFRONT_
|
— |
Lockout Voltage
VCFRONT_
|
V |
Pcs Fault
VCFRONT_
|
— |
Rev Batt Fault
VCFRONT_
|
— |
Vbat Fused Fault
VCFRONT_
|
— |
Show 4 more fields
| Signal | Unit |
|---|---|
Vcleft Fault
VCFRONT_
|
— |
Vcright Fault
VCFRONT_
|
— |
Vcright Lockout Status
VCFRONT_
|
— |
Vehicle State
VCFRONT_
|
— |
Check other alerts