VCFRONT_a160 — Compressor Inhibited

Full alert identifier: VCFRONT_a160_compressorInhibited

Alert description

Operation to the refrigerant compressor is inhibited. HVAC cabin cooling (air conditioning) will be disabled. Powertrain performance may be limited. Refer to related alerts VCFRONT_a136, VCFRONT_a137, VCFRONT_a138, VCFRONT_a139, VCFRONT_a175, VCFRONT_a142, VCFRONT_a247 or (thmlFan) alerts

Potential impact

HVAC cabin cooling (air conditioning) will be disabled. Powertrain performance may be limited.

Set condition

The refrigerant system has a hardware fault, the compressor has an internal fault, or there are abnormal refrigerant system conditions.

Clear condition

Refrigerant compressor operation is no longer inhibited

Signals to check

These diagnostic fields are associated with VCFRONT_a160. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Compressor Rpm VCFRONT_a160_compressorRpm RPM
Fault Sns Ambient Temp VCFRONT_a160_faultSnsAmbientTemp —
Fault Sns Disch Press VCFRONT_a160_faultSnsDischPress —
Fault Sns Disch Temp VCFRONT_a160_faultSnsDischTemp —
Fault Sns Suct Press VCFRONT_a160_faultSnsSuctPress —
Fault Sns Suct Temp VCFRONT_a160_faultSnsSuctTemp —
Fault Valve EXV VCFRONT_a160_faultValveEXV —
Fault Valve Evap Sol VCFRONT_a160_faultValveEvapSol —
Show 6 more fields
Signal Unit
High Disch Pressure VCFRONT_a160_highDischPressure —
High Disch Temp VCFRONT_a160_highDischTemp —
High Discharge Pressure Cutouts VCFRONT_a160_highDischargePressureCutouts —
High Discharge Temp Cutouts VCFRONT_a160_highDischargeTempCutouts —
Low Disch Pressure VCFRONT_a160_lowDischPressure —
Low Suction Pressure VCFRONT_a160_lowSuctionPressure —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a160.