Skip to content

VCDOORFL_a414 — Undervoltage Self Test Failure

Full alert identifier: VCDOORFL_a414_undervoltageSelfTestFailure

Alert description

The Door Vehicle Controller (VCDOOR) self-test did not pass, as a condition affecting a load on the VCDOOR was detected during the self-test.

Potential impact

The vehicle may not allow drive or some loads may not turn on.

Set condition

The VCDOOR undervoltage self-test does not succeed. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.

Clear condition

Successful VCDOOR undervoltage self-test.

Signals to check

These diagnostic fields are associated with VCDOORFL_a414. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Device Stuck On Failure VCDOORFL_a414_deviceStuckOnFailure —
Failure Reason VCDOORFL_a414_failureReason
0
NONE
1
DEVICE STUCK ON
2
BRIDGE
3
BRIDGE AND DEVICE STUCK ON
4
LOAD UNATTEMPTED ON
8
FOLLOWER
16
TIMEOUT
—
Load Unattempted On Failure VCDOORFL_a414_loadUnattemptedOnFailure —
Uv Loadshed Voltage VCDOORFL_a414_uvLoadshedVoltage V
Uv Loadshed Vsense Dig In VCDOORFL_a414_uvLoadshedVsenseDigIn —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFL_a414.

Browse all VCDOORFL alert codes