VCDOORFL_a310 — Mirror Fold Stall
Full alert identifier: VCDOORFL_a310_mirrorFoldStall
Alert description
Mirror stalled unexpectedly while folding or unfolding
Potential impact
Mirror might be halfway between folded and unfolded
Set condition
If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.
Clear condition
Successful mirror fold or unfold
Signals to check
These diagnostic fields are associated with VCDOORFL_a310. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temperature
VCDOORFL_
|
degC |
Folding Direction
VCDOORFL_
|
— |
Mirror Fold Time
VCDOORFL_
|
ms |
Mirror Max Fold Current
VCDOORFL_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFL_a310.