Skip to content

VCDOORFL_a310 — Mirror Fold Stall

Full alert identifier: VCDOORFL_a310_mirrorFoldStall

Alert description

Mirror stalled unexpectedly while folding or unfolding

Potential impact

Mirror might be halfway between folded and unfolded

Set condition

If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.

Clear condition

Successful mirror fold or unfold

Signals to check

These diagnostic fields are associated with VCDOORFL_a310. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temperature VCDOORFL_a310_ambientTemperature
0
SNA
degC
Folding Direction VCDOORFL_a310_foldingDirection
0
FOLD
1
UNFOLD
—
Mirror Fold Time VCDOORFL_a310_mirrorFoldTime ms
Mirror Max Fold Current VCDOORFL_a310_mirrorMaxFoldCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFL_a310.

Browse all VCDOORFL alert codes