VCDOORFL_a122 — eFuse Management Non Continuous16 V

Full alert identifier: VCDOORFL_a122_eFuseManagementNonContinuous16V

Alert description

Unexpected voltage seen on non-continuous device outputs

Potential impact

Electrical loads for mirror tilt up/down, mirror tilt left/right, mirror fold out/in, and mirror motor control may be unavailable.

Set condition

Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven

Clear condition

Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.

Signals to check

These diagnostic fields are associated with VCDOORFL_a122. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
E Fuse Trip Count VCDOORFL_a122_eFuseTripCount —
Non Continuous 16 VE Fuse Monitor VCDOORFL_a122_nonContinuous16VEFuseMonitor V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFL_a122.

Browse all VCDOORFL alert codes