Skip to content

UMC_a016 — Pcba OT Foldback

Full alert identifier: UMC_a016_pcbaOTFoldback

Alert description

UMC PCBA temperature is causing output current reduction

Potential impact

UMC will reduce reported current capability by half until the PCBA cools sufficiently

Set condition

UMC PCBA temperature has risen above 90 C

Clear condition

UMC PCBA temperature has fallen below 88 C

Signals to check

These diagnostic fields are associated with UMC_a016. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pcba Temp UMC_a016_pcbaTemp degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a016.