Skip to content

UMC_a013 — SA Temperature

Full alert identifier: UMC_a013_SA_Temperature

Alert description

Timeout while UMC attempted to read smart adapter temperature

Potential impact

UMC will only report 8 A charge current capability until the smart adapter temperature can be determined

Set condition

UMC was unable to read smart adapter temperature after several retries

Clear condition

UMC succesfully reads smart adapter temperature

Signals to check

These diagnostic fields are associated with UMC_a013. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
SA Current UMC_a013_SA_current A
SA Region UMC_a013_SA_region —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a013.

Browse all UMC alert codes