Alert description

UMC detected contactor stuck open or closed

Potential impact

UMC will not allow charging if the contactor is stuck in an unexpected state. Charge handle pins may be live and hazardous. Stuck open (non-hazardous) contactors will not trigger this fault with EU smart adapters.

Set condition

UMC contactor is open when it should be closed (non-EU smart adapter) or closed when it should be open for several seconds

Clear condition

UMC contactor is in the expected state for several seconds

Signals to check

These diagnostic fields are associated with UMC_a006. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Fault Type UMC_a006_faultType
0
WELDED
1
OPENED
—
Handle Voltage UMC_a006_handleVoltage V
Line 1 Stuck Closed UMC_a006_line1StuckClosed —
Line 2 Stuck Closed UMC_a006_line2StuckClosed —
Output Voltage UMC_a006_outputVoltage Vrms
Umc Receptacle Voltage UMC_a006_umcReceptacleVoltage V