Skip to content

UI_a231 — Sleep Cancelled

Full alert identifier: UI_a231_SleepCancelled

Alert description

The User Interface (UI) detects the command to go to sleep was cancelled.

Potential impact

The UI may appear to be unresponsive while aborting the sleep attempt.

Set condition

The Gateway (GTW) sets the signal GTW_ethGoToSleep=0 after the UI has began preparing for or entering sleep. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

The UI successfully aborts sleep attempt or wakes from its sleep attempt.

Signals to check

These diagnostic fields are associated with UI_a231. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Sleep Type UI_a231_sleepType
0
Shallow
1
S3
2
S2Idle
3
Unknown
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UI_a231.