TAS_a210 — Out Of Range Calibration

Full alert identifier: TAS_a210_outOfRangeCalibration

Alert description

Received ride height sensor calibration values are outside of allowable range.

Potential impact

Air suspension will level to incorrect ride height.

Set condition

Received ride height sensor calibration values are outside of allowable range.

Clear condition

Received ride height sensor calibration values are inside of allowable range.

Signals to check

These diagnostic fields are associated with TAS_a210. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Height Sensor Delta FL TAS_a210_heightSensorDeltaFL mm
Height Sensor Delta FR TAS_a210_heightSensorDeltaFR mm
Height Sensor Delta RL TAS_a210_heightSensorDeltaRL mm
Height Sensor Delta RR TAS_a210_heightSensorDeltaRR mm