TAS_a178 — Wade Fault
Full alert identifier: TAS_a178_wadeFault
Alert description
The Tesla Air Suspension (TAS) electronic control unit (ECU) detects Wade functionality is unavailable due to inability to keep the high voltage (HV) battery pack pressurized.
Potential impact
Wade functionality is not available.
Set condition
TAS ECU detects inability to support Wade functionality. Alert log signal data should provide more information on how the system was unable to pressurize the HV pack due to hardware issues related to airlines, pressure sensor, or valves.
Clear condition
Vehicle-power-state cycle from off to on.
Signals to check
These diagnostic fields are associated with TAS_a178. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Blocked Or Open Airline Detected
TAS_
|
— |
Constant Pressure Check Failed
TAS_
|
— |
Hv Pack Pressure Invalid
TAS_
|
— |
Pack Pressure Derivative Too High
TAS_
|
— |
Pack Pressure Timeout
TAS_
|
— |
Reservoir Pressure Low
TAS_
|
— |
Scuba Valve Unavailable
TAS_
|
— |
State
TAS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a178.