Skip to content

TAS_a167 — Damper Valve Comp FR

Full alert identifier: TAS_a167_damperValveCompFR

Alert description

Front right compression damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Potential impact

All dampers will be unpowered.

Set condition

Front right compression damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

These diagnostic fields are associated with TAS_a167. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault TAS_a167_damperValveFault —
Device On State Diagnostics TAS_a167_deviceOnStateDiagnostics —
Drv Device Fault TAS_a167_drvDeviceFault —
Drv Device Over Current TAS_a167_drvDeviceOverCurrent —
Drv Device Over Temperature TAS_a167_drvDeviceOverTemperature —
Drv Device Over Voltage TAS_a167_drvDeviceOverVoltage —
Drv Device Spi Comm Error TAS_a167_drvDeviceSpiCommError —
Drv Device Under Voltage TAS_a167_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication TAS_a167_drvFailedCommunication —
Drv Output Gnd Short TAS_a167_drvOutputGndShort —
Drv Output Open Circuit TAS_a167_drvOutputOpenCircuit —
Drv Output Over Current TAS_a167_drvOutputOverCurrent —
Drv Output Vm Short TAS_a167_drvOutputVmShort —
Drv Power On Reset TAS_a167_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a167.

Browse all TAS alert codes