Skip to content

TAS_a135 — Valve Fault Boost

Full alert identifier: TAS_a135_valveFaultBoost

Alert description

Tesla Air Suspension (TAS) has detected an electrical issue affecting air suspension boost valve functionality.

Potential impact

Air suspension features may be unavailable or may not function as expected.

Set condition

The TAS ECU detects an electrical condition with the air suspension boost valve. Alert log signal data should provide more information.

Clear condition

Clears after a vehicle power cycle if no further electrical issue is detected affecting air suspension boost valve functionality.

Signals to check

These diagnostic fields are associated with TAS_a135. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Device On State Diagnostics TAS_a135_deviceOnStateDiagnostics —
Drv Device Fault TAS_a135_drvDeviceFault —
Drv Device Over Current TAS_a135_drvDeviceOverCurrent —
Drv Device Over Temperature TAS_a135_drvDeviceOverTemperature —
Drv Device Over Voltage TAS_a135_drvDeviceOverVoltage —
Drv Device Spi Comm Error TAS_a135_drvDeviceSpiCommError —
Drv Device Under Voltage TAS_a135_drvDeviceUnderVoltage —
Drv Failed Communication TAS_a135_drvFailedCommunication —
Show 6 more fields
Signal Unit
Drv Output Gnd Short TAS_a135_drvOutputGndShort —
Drv Output Open Circuit TAS_a135_drvOutputOpenCircuit —
Drv Output Over Current TAS_a135_drvOutputOverCurrent —
Drv Output Vm Short TAS_a135_drvOutputVmShort —
Drv Power On Reset TAS_a135_drvPowerOnReset —
Fw Fault TAS_a135_fwFault —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a135.

Browse all TAS alert codes