TAS_a085 — Over Voltage5 V Analog
Full alert identifier: TAS_a085_overVoltage5VAnalog
Alert description
Off board 5V pressure sensor switched supply is measured to be over 5.5V.
Potential impact
Air suspension leveling will be disabled.
Set condition
Off board 5V pressure sensor switched supply is measured to be over 5.5V.
Clear condition
Vehicle-power-state cycle from off to on.
Signals to check
These diagnostic fields are associated with TAS_a085. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Voltage 5 V Analog
TAS_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a085.