TAS_a075 — Under Voltage5 V Off Board
Full alert identifier: TAS_a075_underVoltage5VOffBoard
Alert description
Off board 5V switched supply is measured to be under 4.5V.
Potential impact
Air suspension leveling will be disabled.
Set condition
Off board 5V switched supply is measured to be under 4.5V.
Clear condition
Vehicle-power-state cycle from off to on.
Signals to check
These diagnostic fields are associated with TAS_a075. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Voltage 5 V Off Board
TAS_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a075.