Skip to content

SSFA_a209 — Startup Sequence Failed

Full alert identifier: SSFA_a209_startupSequenceFailed

Alert description

Power steering startup sequence is unsuccessful.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Controller calibration check is unsuccessful, corresponding controller monitor is not responding, or state timeout occurs.

Clear condition

Startup sequence passes. Startup sequence is run during vehicle startup, and the condition may resolve by drive cycling the vehicle.

Signals to check

These diagnostic fields are associated with SSFA_a209. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Failed State SSFA_a209_failedState —
Gate Driver Internal State SSFA_a209_gateDriverInternalState —
Monitor Startup Failed SSFA_a209_monitorStartupFailed —
State Timeout Exceeded SSFA_a209_stateTimeoutExceeded —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFA_a209.

Browse all SSFA alert codes