SSFA_a123 — Motor Unit Faulted
Full alert identifier: SSFA_a123_motorUnitFaulted
Alert description
A condition has been detected which prevents steering motor operation. Alert log signal data should provide more information on specific condition(s) involved.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
Motor control inputs exceed acceptable bounds.
Clear condition
Motor control is reset while inputs are within acceptable bounds. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to reset motor controls.
Signals to check
These diagnostic fields are associated with SSFA_a123. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bus Overvoltage
SSFA_
|
— |
Bus Undervoltage
SSFA_
|
— |
Channel
SSFA_
|
— |
Current Continuity
SSFA_
|
— |
Dc Overcurrent
SSFA_
|
— |
Gate Driver
SSFA_
|
— |
Motor Control
SSFA_
|
— |
Over Temperature
SSFA_
|
— |
Show 7 more fields
| Signal | Unit |
|---|---|
Phase Overcurrent A
SSFA_
|
— |
Phase Overcurrent B
SSFA_
|
— |
Phase Overcurrent C
SSFA_
|
— |
Position Sensor
SSFA_
|
— |
Speed
SSFA_
|
rpm |
Torque
SSFA_
|
Nm |
Voltage
SSFA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFA_a123.