SSFA_a123 — Motor Unit Faulted

Full alert identifier: SSFA_a123_motorUnitFaulted

Alert description

A condition has been detected which prevents steering motor operation. Alert log signal data should provide more information on specific condition(s) involved.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Motor control inputs exceed acceptable bounds.

Clear condition

Motor control is reset while inputs are within acceptable bounds. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to reset motor controls.

Signals to check

These diagnostic fields are associated with SSFA_a123. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Overvoltage SSFA_a123_busOvervoltage —
Bus Undervoltage SSFA_a123_busUndervoltage —
Channel SSFA_a123_channel —
Current Continuity SSFA_a123_currentContinuity —
Dc Overcurrent SSFA_a123_dcOvercurrent —
Gate Driver SSFA_a123_gateDriver —
Motor Control SSFA_a123_motorControl —
Over Temperature SSFA_a123_overTemperature —
Show 7 more fields
Signal Unit
Phase Overcurrent A SSFA_a123_phaseOvercurrentA —
Phase Overcurrent B SSFA_a123_phaseOvercurrentB —
Phase Overcurrent C SSFA_a123_phaseOvercurrentC —
Position Sensor SSFA_a123_positionSensor —
Speed SSFA_a123_speed rpm
Torque SSFA_a123_torque Nm
Voltage SSFA_a123_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFA_a123.

Browse all SSFA alert codes