SEPS_a297 — Rack Preload Abort
Full alert identifier: SEPS_a297_rackPreloadAbort
Alert description
The rack moved unexpectedly during preload for calibration or position detection
Potential impact
Calibration or position detection cannot complete successfully.
Set condition
Rack sensors report rack movement of more than 0.5mm during a single preload cycle.
Clear condition
Cleared immediately.
Signals to check
These diagnostic fields are associated with SEPS_a297. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Displacement
SEPS_
|
m |
Displacement Ok
SEPS_
|
— |
Input Ok
SEPS_
|
— |
Local Force
SEPS_
|
N |
Preload Status
SEPS_
|
— |
Rack Mech State
SEPS_
|
— |
Rack Speed
SEPS_
|
m/s |
Remote Force
SEPS_
|
N |
Show 2 more fields
| Signal | Unit |
|---|---|
Timeout Ok
SEPS_
|
— |
Torque Ok
SEPS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a297.