SEPS_a159 — Current Continuity Fault
Full alert identifier: SEPS_a159_currentContinuityFault
Alert description
Steering motor current continuity is irrational. The sum of the three phase currents is not equal to 0.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
Observed current into motor does not match current exiting.
Clear condition
Current returns to nominal.
Signals to check
These diagnostic fields are associated with SEPS_a159. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Phase A Current
SEPS_
|
A |
Phase B Current
SEPS_
|
A |
Phase C Current
SEPS_
|
A |
Sum Current
SEPS_
|
amp |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a159.